PROCOTE equipment cleaning tips

Main system (Pump, Motor, Scales and Stand)

  • Purge and drain all Procote from the entire plumbing system. Use an air purge connection if supplied, or the lowest drain location.
  • Disconnect the line from the discharge side of the pump and contain product.
  • Run crop oil, canola oil, or mineral oil through the pump and lines to dilute the Procote. TIP: Run the system in manual mode to get the oil through the pump and drain into a bucket.
  • To help prevent rust, blow or spray off the pump and other components. Address any rust issues by removing the rust, priming, and re-painting these areas.
  • If possible, ensure the power is disconnected from all components to protect from power surges while not in use. Follow automation company’s recommendations.

Agitation Equipment

  • Unhook air hose and remove agitation equipment.
  • Clean agitation equipment .
  • Store in a dust-free, dry area.

Heat Blanket

  • Remove blanket from the tote.
  • Refer to heat blanket manual for cleaning.
  • Refer to heat blanket manual for storage conditions